CERTIFICAZIONI DI PRODOTTO

TEST REPORT N°

ITAH18011510/E1 ‐ Amendment of 31/08/2018

START DATE

END DATE

TEST METHOD

06/08/2018

31/08/2018

Approval Number 2307508

Test Report: MA8028/R

5th July 2023

Cordivari Srl.

ZI Pagliare,

I-64020,

Teramo,

Italy

Water Regulations Approval Scheme Ltd.

Unit 13,

Willow Road,

Pen y Fan Industrial Estate,

Crumlin,

Gwent,

NP11 4EG

WATER REGULATIONS APPROVAL SCHEME LTD. (WRAS)

MATERIAL APPROVAL

Overall Migration

Item for repetead use

REG. 10/2011 EC GU n° L12/1 +

Reg. CE 1935/2004

Heavy Metals Migration

Council of Europe Resolution

cm/res(2013)9 +Reg. CE

1935/2004

PAA ‐ Promary Aromathic Amine

Reg. 10/2011 EC GU n° L12/1 +

Reg. CE 1935/2004

Dyes Migration

D.M 34 of 21.3.73 and

Amendments + Reg. CE 1935/2004

SAMPLE DESCRIPTION

01

01

01

01

PARAMETERS

Simulant

Test Conditions

Amount

Sample Area/Simulant

Volume Ratio

Simulant

Test Conditions

Amount

Sample Area/Simulant

Volume Ratio

Simulant

Test Conditions

Amount

Sample Area/Simulant

Volume Ratio

Simulant

Test Conditions

Amount

Sample Area/Simulant

Volume Ratio

Simulant

Test Conditions

Barium

Cobalt

Copper

Iron

Manganese

Zinc

Lithium

Alluminium

Simulant

Test Conditions

PAA ‐ Sum of Primary

Aromatic Amines

Simulant

Test Conditions

Optical Trasmittance

Simulant

Test Conditions

Optical Trasmittance

Simulant

Test Conditions

Optical Trasmittance

RESULT

U.M.

LIMITS

LQ

Ethanol 10%

4h; 100°C

<1 mg/dm2

1

0

1

0,3 dm2/dL

Acetic Acid 3%

4h; 100°C

<1 mg/dm2

1

0

1

0,3 dm2/dL

Ethanol 95%

7h; 60°C

1,3 mg/dm2

1

0

1

0,3 dm2/dL

Isoctane

3h; 60°C

<1 mg/dm2

1

0

1

0,3 dm2/dL

Acetic acid 3%

10 days; 40°C

< 0,1 mg/kg

1

0,1

< 0,04 mg/kg

0,05

0,04

<1 mg/kg

5

1

<5 mg/kg

48

5

< 0,1 mg/kg

0,6

0,1

< 2,5 mg/kg

5

2,5

< 0,1 mg/kg

0,6

0,1

< 0,1 mg/kg

1

0,1

Acetic acid 3%

4 h; 100°C

< 0,01 mg/kg

0,01

0,01

Ethanol 10%

4h; 100°C

98

T%

>95

Acetic Acid 3%

4h; 100°C

98

T%

>95

Ethanol 20%

4h; 100°C

97

T%

>95

NOTES

LAB

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

ITA

The material referred to in this letter is suitable for contact with wholesome water for domestic purposes having met the

requirements of BS6920-1:2000 and/or 2014 'Suitability of non-metallic products for use in contact with water intended for human

consumption with regard to their effect on the quality of the water'.

The reference relates solely to its effect on the quality of the water with which it may come into contact and does not signify the

approval of its mechanical or physical properties for any use.

COATINGS, PAINTS & LININGS- FACTORY APPLIED PIPE & FITTINGS COATINGS.

5030

'Polywarm'.

Factory applied, brown coloured enamel powder coating. Apply as per manufacturer's instructions '1024'. Cure for 20

minutes@240°C.

For use with water up to 85°C.

APPROVAL NUMBER: 2307508

APPROVAL HOLDER: CORDIVARI SRL.

The Scheme reserves the right to review approval.

Approval 2307508 is valid between July 2023 and July 2028

An entry, as above, will accordingly be included in the Water Fittings Directory on-line under the section headed, “Materials which

have passed full tests of effect on water quality”.

The Directory may be found at: www.wrasapprovals.co.uk/approvals-directory/

Yours Faithfully

Ian Hughes

WRAS Approvals Manager

The Water Regulations Approval Scheme Ltd. Registered in England No, 1303284 Registered office: 6D Lowick Close, Hazel Grove, Stockport, SK7 5ED

WRAS.Appr-305F1 ver 2.0

Tel:+44(0)1495 244 666 Fax:+44(0)1495 244 666 Email:info@wrasapprovals.co.uk website:www.wrasapprovals.co.uk

Page 1 of 9

Intertek Italia S.p.a.

Administrative Office Via Miglioli, 2/A ‐ 20063 Cernusco Sul Naviglio (MI)

Operational Office Via di Stagno 17 F/G ‐ 50055 Lastra a Signa (FI)

Tel. 0039055790873 Fax 0039055791198

page

3 di 4

Rapporto di prova del trattamento interno alimentare Polywarm

®

in conformità al D.M. nr. 174 del 06/04/04.

Certificazione di conformità Polywarm

®

secondo EN 16421.

Certificato di conformità POLYWARM

®

secondo WRAS.

Certificazione di conformità Polywarm

®

secondo il NIZP - Istituto

Nazionale di Igiene Pubblica - Polonia .

203