FLOAT SWITCH FOR WATER UP TO 95°C

USE

Double Pole Probe with vertical action float switch

complete with SIlicon cable, for NO CONDUCTIVE

LIQUIDS, NOT FLAMMABLE LIQUIDS and WATER up

to 95 °C.

110

To determine a level drop, of the controlled liquid, of

more than 1,5 - 2 cm, it is necessary to fit 2 regulators,

one at the highest and one at the lowest level point,

or to arrange a regulator timed intervention.

HAP

Lunghezza cavo indicare i metri es:

indicate the electrode lenght, e.g:

5 metri = 05 - meters cable lenght

10 metri = 10 - meters cable lenght

Passacavo

0 = senza passacavo- without cable gland

1 = passacavo 1” incluso - complete with 1” cable gland

2 = passacavo 1” 1/4 incluso

complete with 1”1/4 cable gland

3 = passacavo sospeso

Tipo cavo - Cable Type

guaina silicone standard silicone cable

1: guaina in poliuretano per gasolio e miscele di acqua ed idrocarburi

polyurethane sheath for diesel oil and hydrocarbons mixture

MATIC · 87 · MATIC

S

onda NGC

REGOLATORE DI LIVELLO PER ACQUA

FINO A 95°C

IMPIEGO

Sonda Bipolare con galleggiante ad

azionamento verticale, completa di cavo in

Silicone, per LIQUIDI NON CONDUTTIVI, NON

INFIAMMABILI ED ACQUA FINO A 95° C

Per determinare un salto di livello del liquido

controllato oltre 1,5 cm occorrono due

regolatori montati in corrispondenza del

punto max. e min. livello, oppure determinare

un intervento temporizzato del regolatore.

MAX 25 VA

4

4

4

4

CODIFICAZIONE

TENSIONE ESERCIZIO

CARICO RESISTIVO

IP

TEMPERATURA ACQUA

PRESSIONE MAX

TIPO CONTATTO

RATED VOLTAGE

RESISTIVE LOAD

WATER TEMPERATURE

MAX PRESSURE

CONTACT FORM

MAX 24V c.a.

max 0,6 A

68

95°C

CAVO SILICONE

1 BAR

SPST