SENSORI GAS ANALIZZATORI INDUSTRIALI

GAS

CODICE

CAMPO DI

RISOLUZIONE

PRECISIONE

CHEMIST

CHEMIST

MISURA

600/600 BG

900/900 RACK

O2

*

AACSE15 0 .. 25% v/v

0,1% vol

±0,2% vol

O2 Long Life

AACSE44 0 .. 25% v/v

0,1% vol

±0,2% vol

CO / H2

AACSE12

0 .. 8000 ppm

±10 ppm

1 ppm

±5%

±10%

0 .. 200 ppm

201 .. 2000 ppm

2001 .. 8000 ppm

CO / H2 Low

AACSE24 0 .. 500,0 ppm

0,1 ppm

±2 ppm

Range

±5%

0 .. 40,0 ppm

40,1 .. 500,0 ppm

CO

AACSE17 0 .. 10.00% Vol

0,01% vol

±0.1% vol

(100.000 ppm)

±5%

0 .. 2.00 %

2.01 .. 10.00 %

CO

AACSE18

0 .. 20000 ppm

±100 ppm

1 ppm

±5%

±10%

0 .. 2000 ppm

2001 .. 4000 ppm

4001 .. 20000 ppm

CO2 NDIR

AACSE47 0 .. 50% v/v

0,1% vol

±1%

±2%

0 .. 10 %

10 .. 50 %

NO

AACSE10 0 .. 5000 ppm

1 ppm

±5 ppm

±5%

0 .. 100 ppm

101 .. 5000 ppm

NO Low Range

AACSE25 0 .. 500.0 ppm

0,1 ppm

±2 ppm

±5%

0 .. 40.0 ppm

40,1 .. 500,0 ppm

NO2

AACSE14 0 .. 1000 ppm

1 ppm

±5 ppm

±5%

0 .. 100 ppm

101 .. 1000 ppm

NO2 Low Range AACSE26 0 .. 500.0 ppm

0,1 ppm

±2 ppm

±5%

0 .. 40.0 ppm

40,1 .. 500,0 ppm

SO2

AACSE13 0 .. 5000 ppm

1 ppm

±5 ppm

±5%

0 .. 100 ppm

101 .. 5000 ppm

SO2 Low Range AACSE28 0 .. 500,0 ppm

0,1 ppm

±2 ppm

±5%

0 .. 40.0 ppm

40,1 .. 500,0 ppm

CH4 NDIR

AACSE73 0 .. 100% v/v

0,01% Vol

0 .. 10%

10 .. 100%

0,3% Vol

10% v.m.

CxHy

AACSE39

0 .. 5,00% Vol

0,01% vol

±0,25% vol

CH4

H2/CO Dual

**

AACSE79

H2

0 .. 2000 ppm

CO

0 .. 8000 ppm

1 ppm

1 ppm

± 10 ppm

± 10 %

±10 ppm

±5%

±10%

0 .. 100 ppm

100 .. 2000 ppm

0 .. 200 ppm

201 .. 2000 ppm

2001 .. 8000 ppm

H2 High

AACSE78

0 .. 40000 ppm

10 ppm

± 100 ppm

± 10 % v.m.

0 .. 1000 ppm

1001 .. 40000 ppm

H2S

AACSE72

0 .. 5000 ppm

+/- 5 ppm

1 ppm

+/- 5% v.m

+/- 10% v.m

0 .. 100.0 ppm

100,0 .. 500,0 ppm

501 .. 5000 ppm

H2S Low Range AACSE35 0 .. 500,0 ppm

0,1 ppm

±5 ppm

±5% v.m.

0 .. 100.0 ppm

100.1 .. 500.0 ppm

NH3

AACSE56 0 .. 500,0 ppm

0,1 ppm

+/-10 ppm

+/-10% v.m.

0 .. 100,0 ppm

100.1 .. 500,0 ppm

(*) Sensore sostituibile dall’utente.

(**) Per Chemist 600, 900 e 900 RACK l’installazione di AACSE79 occupa 2 posizioni sensore. Con questo sensore non è necessario

installare AACSE12 per la misura di CO.

36 Catalogo Analisi e Strumentazione 2025