RECOVERY - RECYCLING
RECOVER
RECYCLE
REUSE
INCLUDED
R32
INCLUDED
R1234ze
COMPLIANCE
ISO 11650
IEC60335-2-104
NF EN35421
CE N.1005 2009
UE-517/2014
EASYREC-1R
Recovery and recycling unit suitable for
CFC, HCFC, HFC and HFO (included R32 and R1234ze)
• Compact design with integrated distiller.
• Distillation device with liquid refrigerant flow check, which allows to
separate oil/impurities/dyes very efficiently.
• Self-evacuation system (PURGE) which allows to change the type of re-
frigerant easily.
• Automatic stop of the unit when there is no refrigerant available in the
system.
• Signal LED (green/cycle performed successfully - red/alarm).
• Safety device for maximum pressure.
• Two cut-off valves to prevent refrigerant discharge.
• “Pulse free” gauges with regulation screw.
• Ceramic cylinder with carbon fiber seal.
• Sight glass and filter included.
• Wide graphics with quick functioning instructions.
Code
Model
Dimensions with pack
13001020 EASYREC-1R 545 x 300 x 395 mm
Technical features
Weight with pack
18,9 kg
CERAMIC CYLINDER
WITH CARBON
FIBER SEAL
REGULATION UE-517/2014 AND 2024 UPDATE
ARTICLE 13 – CONTROL OF USE
From 1
st
January 2020, the use of fluorinated greenhouse gases, with a global
warming potential of 2500 or more, to service or maintain refrigeration equipment
with a charge size of 40 tonnes of CO2 equivalent or more, is prohibited. From 1
st
January 2025, it is planned to extend this ban to all refrigeration systems regardless
of the refrigerant charge.
In accordance with Article 13 Paragraph 3 Subparagraph b), until 1
st
January 2030
recycled fluorinated greenhouse gases with a global warming potential of 2500 or more
contained in refrigeration equipment with a load size equal to or greater than 40 tonnes of
CO2 equivalent may be used for the maintenance or repair of existing refrigeration
equipment, provided they have been recovered from such equipment.
Such recycled gases may only be used by the undertaking which carried out their recovery
as part of maintenance or servicing or the undertaking for which the recovery was carried
out as part of maintenance or servicing. Regulation (EU) No. 517/2014 Article 2 point 15
and the new Regulation Article 3 point 12 define ‘recycling’ as the re-use of a recovered
fluorinated greenhouse gas after a basic cleaning process.
Refrigerant
Power supply
Motor power
Maximal current draw
Compressor
Automatic safety
shut-off
Operating
temperature
Recovery rate
Vapour
Liquid (recovery)
Liquid (recovery-recycling)
Push-pull
•
•
•
•
CFC, HCFC, HFC and HFO
(included R32 and R1234ze)
220 - 240V AC 50 - 60 Hz
550W
4A
Piston-type and oil less
38.5 bar/3850 kPa (558 psi)
0 - 40 oC
Integrated distillation system
R1234ze-
R134a
14 kg/h
96 kg/h
16 kg/h
276 kg/h
R502-
R407C
15 kg/h
108 kg/h
17 kg/h
336 kg/h
R404A-R410A-
R507-R32
16 kg/h
132 kg/h
18 kg/h
378 kg/h
Oil
discharge
High-efficiency heat exchanger
Automatic flow control
Refrigerant
output
Refrigerant
input
HIGH heat exchange between “warm” refrigerant
and “cold” refrigerant, that allows to optimize the
distillation procedure
Automatic flow control system
Max filling up control
Distillation device which allows to separate
oil/impurities/dyes very efficiently
16