HA 8-5 OS 230 V
Distanza dalla sorgente di calore in m
Potenza sonora
in dB(A)
K
T
K
O
1
2
3
4
5
6
8
10
12
15
K
R
Livello di valutazione in dB(A)
Modalità diurna
56
0
3
48,0
42,0
38,5
36,0
34,0
32,4
29,9
28,0
26,4
24,5
0
6
51,0
45,0
41,5
39,0 37,0
35,4
32,9
31,0
29,4
27,5
9
54,0
48,0
44,5
42,0
40,0
38,4
35,9
34,0
32,4
30,5
Modalità notturna
(40% di riduzione
della potenza del
compressore)
52
0
3
44,0
38,0
34,5
32,0
30,0
28,4
25,9
24,0
22,4
20,5
—
6
47,0
41,0
37,5
35,0
33,0
31,4
28,9 27,0
25,4
23,5
9
50,0
44,0
40,5
38,0
36,0
34,4
31,9
30,0
28,4
26,5
Modalità notturna
(50% di riduzione
della potenza del
compressore)
50
0
3
42,0
36,0
32,5
30,0
28,0
26,4
23,9
22,0
20,4
18,5
—
6
45,0
39,0 35,5
33,0
31,0
29,4
26,9 25,0
23,4
21,5
9
48,0
42,0
38,5
36,0
34,0
32,4
29,9
28,0
26,4
24,5
Modalità notturna
(60% di riduzione
della potenza del
compressore)
48
0
3
40,0
34,0
30,5
28,0
26,0
24,4
21,9
20,0
18,4
16,5
—
6
43,0
37,0
33,5
31,0
29,0 27,4
24,9
23,0
21,4
19,5
9
46,0
40,0
36,5
34,0
32,0
30,4
27,9
26,0
24,4
22,5
Riduzione della
potenza del com-
pressore di:
Potenza
sonora ai sensi
della norma EN
12102
[dB(A)]
Velocità compressore
max.
[giri/min]
Velocità ventilatore max.
[giri/min]
Potenza termica per A-7/
W35 in conformità a
DIN EN 14511
[kW]
COP per A-7/W35 in
conformità a
DIN EN 14511
40%
52,0
72
507
4,2
3,1
50%
50,1
60
478
3,5
3,2
60%
48,4
50
450
2,8