Unit R32
compatible
R410A
10,5kW
12,5kW
Flusso +
14,0kW
5 Velocità
COMANDI OPTIONAL
PER I COMANDI
CONSULTARE LA SEZIONE
SISTEMI DI CONTROLLO
On-Off Card
Quite
Fresh Air
UNITà INTERNA
Modello
AC105S2SH1FA
AC125S2SK1FA
AC125S2SK1FA
AC140S2SK1FA
AC140S2SK1FA
Codice commerciale
2501408A2
2501409A2
2501409A2
2501409B2
2501409B2
UNITà ESTERNA
Modello
1U105S2SS1FA
1U125S2SN1FA
1U125S2SN1FB
1U140S2SP1FA
1U140S2SP1FB
Codice commerciale
2502308A2
2502309A2
2502309B2
2502309D2
2502309F2
Dati prestazionali
Potenza resa RAFF.
nom (min~max)
kW
9,5 (2,5-10,0)
12,1 (3,0~12,8)
12,1 (3,0~12,8)
13,1 (3,0~14,5)
12,9 (3,0~14,5)
Potenza resa RISC
nom (min~max)
kW
10,2 (3,0-10,5)
12,5 (2,9~13,5)
12,6 (2,9~13,5)
14,5 (3,5~16,0)
14,1 (3,5~16,0)
Potenza assorbita RAFF.
nom (min~max)
kW
3,22 (0,5-4,0)
4,3 (0,3~5,6)
4,2 (0,3~5,6)
4,37 (1,0~7,2)
4,43 (1,0~7,2)
Potenza assorbita RISC.
nom (min~max)
kW
3,16 (0,5-4,0)
3,8 (0,3~5,6)
3,7 (0,3~5,6)
3,92 (1,0~7,7)
4,02 (1,0~7,2)
Classe energetica
EER
3,04
2,75
2,73
3,0
2,91
COP
3,32
3,25
3,21
3,70
3,51
Pdesign RAFF.
capacità (35°)
kW
9,5
12,1
12,1
13,4
13,4
Pdesign RISC.
capacità (-10°)
kW
7
8,3
8,3
11
11
Classe energetica
SEER
6,11 (A++)
5,86
5,86
6,3
6,1
SCOP
3,8 (A)
3,81
3,81
3,9
4,0
Consumo annuo di energia RAFF.
kWh/a
549
728
728
743
760
Consumo annuo di energia RISC.
kWh/a
2750
3052
3052
3951
3865
Unità interna
Alimentazione
Ph-V-Hz
1/220~240/50/60
1/220~240/50/60
1/220~240/50/60
1/220~240/50/60
1/220~240/50/60
Volume aria trattato
m
3
/h
1600/1400/1280/1160
2050/1900/1600/1400
2050/1900/1600/1400
2150/1980/1800/1600
2150/1980/1800/1600
Potenza sonora
dB
62
64
64
66
66
Pressione sonora
dB(A)
44/41/38/36
46/43/41/38
46/43/41/38
48/46/43/40
48/46/43/40
Dimensioni
L x Px H
mm
1325x230x680
1650x230x680
1650x230x680
1650x230x680
1650x230x680
Peso netto
kg
33
44
32
44
44
Unità esterna
Alimentazione
Ph-V-Hz
1/220~240/50/60
1/220~240/50/60
3/380~415/50/60
1/220~240/50/60
3/380~415/50/60
Volume aria trattato
m
3
/h
3500
4000
4000
7000
7000
Potenza sonora
dB
66
68
68
70
70
Pressione sonora
dB(A)
53
52
52
53
53
Dimensioni
L x Px H
mm
920x372x760
965x950x370
965x950x370
1350x950x370
1350x950x370
Peso netto
kg
65
82
83
105
108
Tipo compressore
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Marca compressore
Dati Idraulici
Refrigerante
R32
R32
R32
R32
R32
Tubazione liquido Ø
mm
9,52
9,52
9,52
9,52
9,52
Tubazione gas Ø
mm
15,88
15,88
15,88
15,88
15,88
Lunghezza tubazioni std senza carica refrigerante
m
30
30
30
30
30
Lunghezza tubazioni max
m
50
50
50
75
75
Carica refrigerante in fabbrica
kg
1,5
2
2
2,9
2,9
Dislivello max UI - UE
m
30
30
30
30
30
Tonnellate equivalenti di CO
2
kg/tCO
2
EQ
1,0
1,35
1,35
1,9
1,9
Carica aggiuntiva ref. oltre lungh. std.
g/m
45
45
45
45
45
Limiti di funzionamento RAFF.
min~max
°C
21÷35°C (in) / -10÷46°C (out)
21÷35°C (in) / -15÷52°C (out)
Limiti di funzionamento RISC.
min~max
°C
10÷27°C (in) / -15÷24°C (out)
10÷27°C (in) / -20÷24°C (out)
haiercondizionatori.it
9